Grease trap
Grease trap
Grease trap
A waste water treatment plant was having problems with impurities and fibers contained in the grease intake trap. This led to more time spent on maintenance and cleaning at a later stage in the plant.
A Börger Multicrusher was installed in the grease trap station in the plant. Using a pressure pipe, the suction unit forces the sludge through the Multicrusher into the waste water treatment plant. To protect against very large contaminants and impurities, a small rock trap is integrated at the input flange. The Multicrusher also has an auto reversing control unit to protect against sudden jamming of the unit.
Technical data
Macerator | Multicrusher |
---|---|
Medium | Grease |
Throughput volume | 200 m³/h (880 usgpm/h) |
Speed | 100 rpm |